Best RV Tankless Water Heater: Retrofit Picks and Flow Requirements
Last checked:
The best RV tankless water heater fits the existing opening, works with the RV's water flow, and supplies useful hot water at the inlet temperatures you expect. For a low-flow shower, Furrion publishes a 0.32 GPM operating minimum. For stop-start use, Truma AquaGo comfort has a mixing vessel that helps steady the outlet temperature. We compared manufacturer ratings and installation drawings for six propane heaters without hands-on testing. Have a qualified RV service technician verify the fit and install the heater.
Quick picks
| Pick | Best for | Key spec |
|---|---|---|
| Girard GSWH-2 / 2GWHAM | Retrofit planning with separate door selection | 42,000 BTU/h; 0.60 GPM manual minimum |
| Furrion FWH09AFA-AM | Low minimum operating flow | 60,000 BTU/h nominal input; 0.32 GPM minimum |
| Fogatti InstaShower 8 Plus | Several exterior door configurations | 55,000 BTU/h input, up to 2.9 GPM |
| Truma AquaGo comfort | Stabilizing temperature between faucet cycles | 20,000-60,000 BTU/h input |
| Suburban ST-60 | An on-demand heater with wall controls | 0.7 GPM minimum flow |
| RecPro RP-1057-42BTU | Comparing a heater-and-door configuration | 13 × 13 in wall opening |
Minimum flow and maximum advertised flow describe different things. These figures do not establish a ranking for simultaneous showers or cold-weather output.
Some links on this page are affiliate links that may earn us a commission at no extra cost to you. Affiliate disclosure
-
Girard Tankless RV Water Heater GSWH-2 / 2GWHAM
Girard
Best for: A documented retrofit with a separately selected door
- 42,000 BTU/h
- 0.60 GPM per hot faucet in June 2025 owner’s manual
- 13 x 13-inch rough opening
-
Furrion Tankless Gas Water Heater FWH09AFA-AM
Furrion
Best for: A low published minimum flow with antifreeze equipment
- 60,000 BTU/h nominal input
- Manufacturer-rated 2.4 GPM
- 0.32 GPM minimum flow
-
InstaShower 8 Plus RV Tankless Water Heater
Fogatti
Best for: Choosing from several exterior door sizes
- 55,000 BTU/h heat input
- Up to 2.9 GPM
- 13 x 13-inch minimum opening
-
Truma AquaGo comfort
Truma
Best for: Temperature stabilization during stop-start use
- 20,000-60,000 BTU/h nominal input
- Burner starts above approximately 0.4 GPM
- Temperature-stabilizing mixing vessel
-
ST-60 Tankless Water Heater 5382A
Suburban
Best for: A Suburban model with documented minimum flow
- 8,000-60,000 BTU/h input range
- 0.7 GPM minimum flow
- Freeze protection requires power and propane
-
RV Tankless Water Heater RP-1057-42BTU
RecPro
Best for: A 42,000 BTU option with selectable door sizes
- 42,000 BTU rating
- Approximately 0.7 GPM manual flow requirement
- 15 x 15-inch or 18 x 18-inch door options
Girard GSWH-2 / 2GWHAM
The Girard tankless water heater, Lippert part 2022107534, is the GSWH-2 platform sold under the 2GWHAM reference. Its manual specifies 42,000 BTU/h and a 13-by-13-inch rough opening. Girard’s June 2025 owner’s manual calls for at least 0.60 GPM at each hot-water faucet it supplies. The service manual also describes an earlier 0.70 GPM start specification. For an existing unit, match the documentation to its revision.
The heater-only package includes the digital control panel. Order the door for the old heater’s opening. Girard’s GSWH-2 manual identifies an Intertek ETL listing to ANSI Z21.10.3-2014 and CSA 4.3-2014 for this RV appliance.
The limitation is that neither the brand name nor the previous heater's tank capacity proves fit. Match the actual heater, door kit, cabinet space, and vent arrangement. Its winter-use mode also depends on propane and electrical power and protects the heat exchanger, not all plumbing elsewhere in the RV.
Furrion FWH09AFA-AM
The Furrion FWH09AFA-AM has built-in antifreeze protection. The exact model suffix matters when you compare it with other Furrion heaters. Lippert lists a 60,000 BTU/h nominal input and 2.4 GPM capacity. Its model-family manual specifies a minimum operating flow of 0.32 GPM.
The low operating minimum matters if a water-saving showerhead restricts flow. The 2.4 GPM figure is the product’s rated capacity. Your shower may deliver less hot water when campground water comes in cold.
The limitation is that antifreeze protection is conditional. The manual requires the appliance, house electrical supply, and gas supply to remain on for that function. It also requires winterization for storage and says the heater's protection does not protect the coach's entire water system. Do not transfer those features to a different Furrion suffix.
Fogatti InstaShower 8 Plus
The InstaShower 8 Plus is Fogatti's selected current configuration here. Its page lists 55,000 BTU/h heat input, up to 2.9 GPM, and a minimum opening of 13 by 13 inches. Available door dimensions include 15 by 15, 15 by 18, and 18 by 18 inches.
Those options make it a useful model to compare when the exterior opening needs particular coverage. Have the technician select the door and any supporting components from the existing opening, rather than assuming the largest door is the correct choice.
The limitation is that the maximum flow figure does not describe every inlet temperature or installation. It also should not be confused with a minimum activation rate. Confirm that requirement for the supplied version, and follow Fogatti's winterization guidance instead of treating freeze protection as a storage guarantee.
Truma AquaGo comfort
The Truma AquaGo comfort combines on-demand heating with a temperature-stabilizing mixing vessel. Truma lists a nominal input range of 20,000 to 60,000 BTU/h. Its operating description says the burner starts when flow exceeds approximately 0.4 GPM.
The mixing vessel is an important distinction for owners comparing stop-start shower use. This is not simply a large storage-tank heater with a different label, and its small stored water volume should not be confused with a conventional tank's shower capacity.
The limitation is that its maintenance and winterization routine is specific to AquaGo. The Easy Drain Lever and optional electric antifreeze kit have different roles. Confirm the retrofit and service arrangements before purchase, and have the installer explain how to drain, bypass, and maintain this exact model.
Suburban ST-60
The Suburban ST-60, listed as 5382A on the manufacturer page, has an included wall-mounted digital control center. The ST-series manual gives an input range of 8,000 to 60,000 BTU/h and a minimum flow of 0.7 GPM.
If a shower cycles between hot and cold at a low setting, compare the hot-side flow at the fixture with the ST-60’s 0.7 GPM minimum before choosing it. Measure the flow with the showerhead you intend to keep.
The limitation is that an existing Suburban tank heater does not make this an automatic direct replacement. Confirm the opening, door arrangement, utilities, and vent clearance. Suburban describes its active freeze protection as dependent on power and propane being available; that feature does not remove the need for a storage and winterization plan.
RecPro RP-1057-42BTU
The RecPro 42,000 BTU tankless heater is a separate selection from its higher-rated models. Its ordering options include 15-by-15-inch and 18-by-18-inch doors, with other installation choices selected separately.
The shared RP-1057 manual describes a flow requirement of approximately 0.7 GPM. RecPro gives the same threshold as 2.5 liters per minute. Its installation drawing calls for a 13-by-13-inch wall opening and suggests at least 15¾ inches of depth for the appliance and its connections.
The limitation is that the exterior door size does not describe the entire cabinet requirement. Check the heater body, service space, connections, and mounting requirements as well. RecPro also requires gas and power for automatic freezing protection and calls for draining during winter storage. Choose the complete configuration from the actual installation rather than the headline BTU rating alone.
How to choose the best RV tankless water heater
Understand the change from a tank heater
A conventional six- or ten-gallon heater stores hot water and reheats that supply. An RV on-demand water heater heats water as it moves through the appliance, so normal use is not limited by waiting for the main storage tank to recover.
The tradeoff is dependence on operating flow. Opening a hot faucet starts a sequence involving water sensing, ignition, and heating. Water already sitting in the pipe still has to reach the fixture. "Tankless" therefore does not promise immediate hot water at a distant shower.
Some systems include a small mixing or stabilization vessel. Compare how the exact model manages temperature changes, not just whether a retailer calls it tankless.
Read BTU and GPM together
BTU/h describes a heating input or rating as identified by the manufacturer. GPM describes water flow. A maximum GPM claim without the associated temperature conditions does not tell you what the heater will deliver from a cold campground supply.
Colder inlet water needs a larger temperature rise. The Furrion manual explains that reducing its water flow can improve heating performance under cold inlet conditions. RecPro’s published example for its 42,000 BTU model gives 1.32 GPM with 50°F incoming water and 1.98 GPM with 68°F incoming water. Its chart does not state the outlet temperature. Use those figures to see the effect of colder water on this heater.
Compare the conditions in the manufacturer's performance information. If they are not stated, treat the maximum as a product rating, not a guaranteed shower result or proof that multiple fixtures can run together.
Check minimum activation flow at the fixture
Pressure and flow are related but not interchangeable. A campground connection may show pressure while restrictions prevent enough water from moving through the heater.
Have the technician evaluate flow at the shower and other hot-water fixtures with the actual pump, filters, and plumbing in use. Review our RV water pressure guide and RV showerhead comparisons before changing equipment.
A water-saving showerhead can be useful, but an overly restrictive setting may cause a flow-activated heater to cycle. Adding cold water at the fixture can also reduce flow through the heater. Follow the exact model's temperature-setting and mixing instructions; AquaGo and other designs should not all be operated by one generic rule.
Cutouts, doors, and replacement planning
Measure the structural wall opening, available depth, and exterior door separately. Appliance casing dimensions, rough-opening dimensions, shipping dimensions, and door dimensions are different measurements.
| Heater | What the dimension describes |
|---|---|
| Girard GSWH-2: 13 x 13 inches | Rough opening specified in its installation manual |
| Furrion FWH09AFA-AM: 12⅝–13 inches wide by 12¾–13 inches high | Square-corner opening. Minimum depth is 19¾ inches. Furrion suggests 23½ inches for utilities. |
| Truma AquaGo comfort DLE60C: 12¾ x 12¾ inches | Framed opening with more than 17.7 inches of depth, per Truma’s installation manual, Fig. 13 |
| Fogatti 8 Plus: 13 x 13 inches | Manufacturer-listed minimum opening |
| Fogatti: 15 x 15, 15 x 18, or 18 x 18 inches | Exterior door options |
| RecPro RP-1057: 13 x 13 inches | Wall opening. The separate exterior doors measure 15 x 15 or 18 x 18 inches. |
Use these as model-specific examples, not a universal cutting template. The installer must also check depth, support, corner shape, utility routing, service access, and exhaust clearances.
Girard’s conversion kits have different door options for a six-gallon Suburban, a six-gallon Atwood or Dometic, and a ten-gallon Atwood. Match the old model and measured opening with the new manufacturer's approved kit. A trim ring can cover a perimeter gap; it does not establish safe exhaust routing or correct an unsupported installation. Use only the heater manufacturer's approved door arrangement.
Cold-weather use and boondocking
Active freeze protection is not whole-RV winterization. Girard, Furrion, Suburban, and RecPro document conditions that depend on available energy. Fogatti also advises winterization when the required protection cannot be maintained.
Storage procedures differ. For example, Truma's AquaGo winterization guidance calls for its drain-and-bypass process and cautions against sending antifreeze solution through the appliance. Follow that model's instructions alongside the RV winterization guide.
While boondocking, continuous heating still consumes water, propane, and electrical power. The fresh tank and gray tank remain the practical limits. Stop-start use can also mean waiting for water in the line to warm again. Compare that routine with your actual camping habits using our boondocking guide.
Installation, maintenance, and common mistakes
Have a qualified technician install the heater and verify the fuel, electrical, plumbing, and exterior vent connections. These selected models use propane for heating with electrical power for their operating systems. A low-voltage connection does not make them all-electric water heaters.
Keep combustion-air and exhaust openings clear, and follow the manual's inspection and cleaning schedule. Do not operate a damaged appliance or attempt to repair its gas controls yourself. Have the installer explain shutdown and fault procedures before the first trip.
Common buying mistakes include choosing by maximum GPM alone, reusing an incompatible door, confusing freeze protection with winterization, and overlooking low-flow behavior. Another is applying one brand's descaling method to every heater. Review portable RV water softeners when planning for hard-water supplies, but keep the appliance's prescribed cleaning and maintenance routine.
FAQ
Can a tankless heater replace my RV's six-gallon tank heater?
Often, but the old tank capacity does not establish fit. A technician must compare the wall opening, cabinet depth, exterior door, mounting support, vent position, and utility connections with the new heater's requirements. Approved door and trim kits can help cover a larger opening, but they do not correct every installation mismatch.
Why does my RV tankless water heater turn cold at low flow?
The burner needs enough water moving through the heater to activate and continue operating. A restricted showerhead, clogged filter, unstable pump flow, or excessive cold-water mixing can reduce that flow. Check the exact model's manual before changing settings. Have persistent cycling diagnosed rather than treating higher water pressure as a universal solution.
Does tankless mean unlimited hot showers while boondocking?
No. Heating can continue only while the system has the required water flow, propane, and electrical supply. Fresh-water capacity and gray-tank space still limit shower use. There is also water already cooling in the pipes between the heater and fixture. Tankless removes the main storage-tank recovery wait; it does not remove those camping limits.
Will built-in freeze protection replace winterization?
No. Active protection has model-specific operating conditions and usually depends on an available energy supply. It may protect the heater without protecting the RV's other plumbing. Follow the heater's winterization procedure before storage or when required protection cannot be maintained. Do not assume that a winter-use feature remains effective after power or propane is shut off.
Is an RV tankless water heater electric or propane?
The selected heaters use propane for water heating and require electrical power for controls and related functions. A listing that mentions a low-voltage electrical connection does not mean that connection supplies all the heat. Compare the exact fuel and power requirements with the RV's systems, and have a qualified technician confirm the installation.
Sources
- https://www.lippert.com/girard-tankless-rv-water-heater-2022107534
- https://www.lippert.com/furrion-tankless-gas-water-heater-with-antifreeze-protection-24gpm-white-fwh09afa-am-2021132340
- https://fogatti.com/products/fogatti-rv-tankless-water-heater
- https://www.truma.com/us/products/water-systems-us/aquago-us/truma-aquago-comfort/
- https://suburbanrv.com/water-heating/tankless-water-heaters/st-water-heaters/st60-water-heater/
- https://recpro.com/rv-tankless-water-heater-on-demand-hot-water-heater/
- https://support.lci1.com/documents/ccd-0006120
- https://support.lci1.com/documents/ccd-0009390
- https://lci-support-doc.s3.amazonaws.com/furrion%20documentation/water%20heaters/ccd-0005507.pdf
- https://library.suburbanrv.com/wp-content/uploads/2024/04/206212-1_ODWH-ST42-60-User-Manual-RNew-04-16-2024.pdf
- https://recpro.com/content/RP-1057%20RecPro%20Tankless%20Water%20Heater%20Manual.pdf
- https://www.truma.com/us/time-to-winterize-truma-aquago/
- https://fogatti.com/pages/winterize-your-rv-water-heater
- https://www.lippert.com/girard-water-heater-kit-water-heater-kit
- https://suburbanrv.com/service-support/faqs/
- https://cdn2.olivertraveltrailers.com/wp-content/uploads/2024/05/30121417/Truma-AquaGo-Water-Heater.pdf
- https://support.lci1.com/gp-llc-other-products