What Size Generator for RV Camping? A Practical Sizing Guide

Last checked:

To decide what size generator for RV camping you need, add the running watts of the appliances you expect to use together. Then check the moment of highest demand, often when the air conditioner starts while other equipment is running. Compare those two totals with the generator’s continuous rating and motor-starting capability at your campsite elevation. The outlet and RV cord must also be compatible.

What you need

Gather the information before comparing generator sizes:

  • Appliance manuals or photographs of electrical input labels.
  • The air conditioner's starting requirements and any installed soft-start documentation.
  • Your converter or inverter/charger's AC input information.
  • The generator specification sheet, including rated and maximum output; compare equipment in our RV generator buying guide.
  • Your campsite elevation, generator rules, and the RV's approved connection requirements.

What size generator for RV camping fits your loads?

1. List the appliances that will operate together

Write down air conditioning, cooking appliances, electric water heating, refrigeration, and battery charging. Include automatic loads that may switch on without a reminder.

Use electrical input requirements, not a microwave's cooking-output rating or an air conditioner's BTU cooling capacity. For cooling selection itself, see our RV air-conditioner sizing guide.

Make separate operating plans. Cooling while charging the battery is a different load from cooling while making coffee and heating water electrically.

2. Distinguish rated output from maximum output

Rated or continuous output describes the generator's sustained electrical capacity under the manufacturer's stated conditions. Maximum or starting output is a separate rating; check how long it is available.

For example, Honda lists the EU2200i at 1,800 watts rated and 2,200 watts maximum. The larger advertised figure is not its sustained running allowance.

Use the ratings for the fuel and operating conditions you intend to use. Also check the output voltage, receptacle limits, and the RV manufacturer's connection instructions.

3. Identify the largest starting demand

A compressor can need substantially more power to start than to keep running. The generator must accommodate that event while supporting the other equipment already operating.

For illustration, Cummins' RV sizing guide gives a typical 15,000 BTU/h air conditioner example of 1,500 watts running and 3,500 watts starting. Those are planning figures, not specifications for every unit of that cooling size.

Check whether the appliance maker lists total starting watts or additional starting watts. For a total, substitute it for that appliance’s running watts. For an additional figure, add it once to the running total. If two motors can start together, include their overlapping demand or schedule the starts separately.

Typical sizing figures: check your appliance labels

These are typical - check your appliance labels. Cummins gives the air-conditioner example above. Its RV Generator Handbook supplies the ranges for the other three loads. The worked example uses one value from each range.

Appliance or load Typical running input Value used in example Starting consideration
15,000 BTU/h air conditioner 1,500 W in the Cummins example 1,500 W 3,500 W total during startup in that example
Converter/charger 500–1,000 W for a typical converter 500 W Check AC input while charging a depleted battery
Coffee maker 900–1,200 W 1,000 W Read the input label for the selected brew mode
Electric water heater 1,000–1,500 W Off Add its input if the electric element can switch on

This table is a worksheet starting point, not a model-specific sizing chart. A larger charger, a different air conditioner, or additional appliances can change the result considerably.

Worked example: cooling, charging, and coffee

Suppose the AC, converter, and coffee maker operate together using those illustrative values:

Check Calculation Result
Simultaneous running load 1,500 + 500 + 1,000 3,000 watts
Load while the AC starts 3,500 + 500 + 1,000 5,000 watts
Running load with coffee delayed 1,500 + 500 2,000 watts
Starting load with coffee delayed 3,500 + 500 4,000 watts

The starting calculation replaces the AC's running figure with its starting figure. Do not add both for the same compressor.

The first operating plan needs sufficient continuous capacity for the running load and enough transient capability for the starting event. Delaying coffee lowers both requirements without changing the air conditioner.

These calculations do not guarantee that a particular generator will start a particular compressor. Confirm surge duration, current limits, other background loads, and manufacturer compatibility before selecting the equipment.

How a soft start changes the calculation

A compatible soft start reduces the compressor's initial demand. Micro-Air describes this function for its EasyStart Breeze, which is designed for RV air-conditioning equipment.

It can make a smaller generator workable when compressor startup is the limiting factor. The generator must still carry the AC's running load plus other operating equipment.

Use verified data for the installed combination, and follow the AC and soft-start manufacturers' requirements. Do not subtract an advertised reduction from every appliance or assume it increases the generator's rated output.

Our RV air-conditioner soft-start guide explains compatibility and selection.

Account for altitude and heat

Generator output can fall at elevation and in high temperatures. Apply the rule in the actual generator's operator manual before deciding that the paper load budget fits.

The Cummins handbook gives a derating guideline of 3.5% for each 1,000 feet above 500 feet. Its example at 4,500 feet produces a 14% loss.

At 4,500 feet, the handbook’s illustrative 4,000-watt generator loses 560 watts, leaving about 3,440 watts. That clears the 3,000-watt running example on paper. It still leaves the 5,000-watt start to check against the model’s available starting capacity at that elevation.

Check any altitude-related service requirements with the manufacturer. Do not modify the fuel system yourself to follow a general sizing article.

Sizing for 30-amp and 50-amp RVs

A standard 30-amp RV hookup offers 3,600 watts nominally. Full standard 50-amp service offers 12,000 watts across its two legs, as explained in our 30-amp versus 50-amp RV guide.

Those figures describe shore-service capacity. You do not need to reproduce all of it if you plan to run a smaller selection of appliances.

For a 50-amp coach, verify how the generator and approved connection supply the panel's circuits. A familiar-looking receptacle does not establish full shore-power capacity or guarantee that every appliance is available.

If you want multiple air conditioners operating together, budget their running loads and the likely starting events. Use the coach's load-management instructions and obtain confirmation for the generator configuration.

Using two generators in parallel

Parallel operation can offer more output while allowing the units to be transported separately. It requires generators designed for the task and an approved kit.

Honda’s parallel guide rates two compatible EU2200i units at 3,600 watts continuous and 4,400 watts maximum at 120 volts. Honda limits operation at maximum output to 30 minutes. In the example above, this pair falls short of the 5,000-watt start with coffee brewing even before any altitude adjustment.

Compatibility can depend on the exact model and, for some combinations, serial number. Follow the maker's instructions and receptacle limits rather than connecting generator outputs with improvised cords.

Compare the combined equipment's carrying needs, fuel supply, setup, and campground permission with a single larger unit. More available watts do not change operating-hour restrictions.

CO safety and generator placement

Run a portable generator outdoors. CPSC’s placement guidance calls for at least 20 feet from the home, with exhaust directed away from buildings. At a campsite, measure from the RV itself and allow the same separation from neighboring campers and tents. Keep exhaust away from doors, windows and vents. If the site is too tight to do that, leave the generator off.

Never run a portable unit inside an RV, storage compartment, garage, or other enclosed or partially enclosed space. A CO shutoff feature does not replace safe placement or working RV CO alarms.

A factory-installed RV generator has its own exhaust and ventilation design. Before use, inspect its exhaust as the operator’s manual directs and make sure the RV’s CO alarm works. Leave a unit with a damaged exhaust off until it has been repaired.

If a CO alarm sounds or poisoning is suspected, move everyone to fresh air immediately and call 911. Do not re-enter to investigate the generator yourself.

Campground noise limits and quiet hours

In National Park Service areas, 36 CFR § 2.12(a)(1) prohibits operating a generator above 60 dBA at 50 feet. Noise below that level can still be unreasonable given the time, location and impact on other visitors. A reading at or below the limit does not give permission to run during posted generator-off hours.

For example, Assateague Island National Seashore bars generator operation from 10 p.m. to 6 a.m. In Bayside Loop B, the Oceanside walk-in sites and the group sites, the ban applies all day. Check the rules for the particular campground and loop before relying on a generator overnight.

A manufacturer's noise figure measured at a different distance or load is not direct proof of compliance. Check the conditions behind the rating and the campground's current rules.

For loads you need during generator-off periods, compare battery and inverter options or portable power stations for RV camping. Verify their output, stored energy, and equipment compatibility for the intended use.

Common mistakes

  • Choosing from maximum watts while ignoring the rated output.
  • Counting the AC's running load but omitting compressor startup.
  • Forgetting automatic battery charging or electric water heating.
  • Applying one generic soft-start reduction or altitude rule to every setup.
  • Assuming the shore-cord rating dictates the generator size.
  • Buying before confirming safe placement and campground permission.

FAQ

What size generator do you need for a 30-amp RV?

A full 30-amp hookup supplies about 3,600 watts at 120 volts. You can use a smaller compatible generator if it covers the appliances you run together and their highest combined starting demand. Check continuous output, motor-starting capability at your elevation and the receptacle rating before choosing a model.

Will a 2,200-watt generator run an RV air conditioner?

Compare the air conditioner’s running input and starting demand with the generator’s ratings. For the EU2200i, Honda lists 1,800 watts rated and 2,200 watts maximum. The 3,500-watt compressor start in this article exceeds that maximum. A different unit or a compatible soft start needs its own verified starting figure.

Does a soft start let you ignore the air conditioner's running watts?

No. A soft start addresses the compressor's initial starting demand. The generator must still support the air conditioner's running electrical input along with other equipment operating at the same time. Use the installed soft starter's documentation and verified starting data when revising the budget; do not assume a universal reduction.

Can you connect any two generators in parallel?

No. Both generators and the parallel kit must be approved for that exact combination. Compatibility can depend on model and serial number, and the published combined rated output may differ from the sum of the advertised maximum figures. Follow the manufacturer's connection procedure and all receptacle limits.

Can a quiet inverter generator run during campground quiet hours?

Only if the campground's rules specifically allow that operation. A low noise rating does not override generator-hour restrictions or a generator-free site designation. Check the rules for your assigned campground and loop before planning overnight cooling or charging, and arrange an allowed power alternative when generator operation is prohibited.

Sources

  1. https://powerequipment.honda.com/generators/models/eu2200i
  2. https://www.cummins.com/en-na/generators/rv-generators/rv-generator-electricity-basics
  3. https://mart.cummins.com/imagelibrary/data/assetfiles/0056746.pdf
  4. https://www.microair.net/products/easystart-breeze-soft-starter
  5. https://cdn.powerequipment.honda.com/pe/pdf/manuals/pci54866.pdf
  6. https://www.cpsc.gov/s3fs-public/468-WhattoKnowGenerators_2022.pdf
  7. https://www.ecfr.gov/current/title-36/chapter-I/part-2/section-2.12
  8. https://www.nps.gov/asis/planyourvisit/campground-regulations.htm