What Size RV Air Conditioner Do You Need?
Last checked:
To decide what size RV air conditioner you need, start with the RV maker's approved setup and the heat load you expect. A 13,500 BTU/h unit may suit a smaller cooling task; a 15,000 BTU/h unit adds capacity but cannot solve every airflow or heat-gain problem. Larger, divided living spaces may need another unit. Confirm electrical and generator capacity before choosing, because cooling output and electrical input are different ratings.
What size RV air conditioner fits your needs?
RV length provides a useful starting clue, but it is not a dependable sizing formula. Insulation, glass area, slide-outs, occupancy, direct sun, and outdoor temperature all affect the heat entering the vehicle.
As a rough sizing rule, start with the existing unit’s capacity if it cooled the RV well on similar trips. If only the bedroom gets hot with the door shut, check whether cool air reaches that room. If the entire RV struggles in afternoon sun even with good airflow, ask the RV maker about a higher-capacity unit or a second cooling zone.
If last summer’s setup kept up at this campsite but now struggles in similar weather, inspect the return-air filter and make sure the outlets are clear. Have a technician check a persistent drop in performance before you spend money on a larger unit.
| Situation | Sensible next step |
|---|---|
| Existing system meets your needs | Compare approved replacements of similar capacity |
| Whole interior struggles in direct sun | Reduce heat gain and assess capacity |
| Main room cools but bedroom stays warm | Check distribution and zone needs |
| Cooling recently became weak | Check maintenance, airflow, controls, and power |
| Adding another rooftop unit | Confirm roof, electrical, controls, and installation approval |
Dometic's buying guidance likewise emphasizes vehicle size, insulation, distribution, and installation position. Its sizing principles are useful here; electrical specifications must come from the US model being considered.
13,500 vs 15,000 BTU RV AC
The rating commonly shortened to BTU describes cooling output per hour. It is not electrical wattage.
Moving from 13,500 to 15,000 BTU/h adds 1,500 BTU/h, approximately 11% more nominal capacity. That is a useful increase when the existing capacity is close to adequate, but it is not equivalent to adding another complete air conditioner.
Compare exact models rather than assuming every unit within a size class uses the same electricity. These Coleman-Mach manufacturer examples show the distinction:
| Published specification | Mach 3, 382X3-06X family | Mach 15, 382X4-06X family |
|---|---|---|
| Nominal cooling capacity | 13,500 BTU/h | 15,000 BTU/h |
| Total cooling full-load current at standard test conditions | 13.0A | 14.7A |
| Cooling running input at standard test conditions | 1,420W | 1,606W |
| Cooling running input at the maker's desert test conditions | 1,672W | 1,988W |
| Compressor locked-rotor current | 60.5A | 60A |
Coleman-Mach tested these units with outdoor air at 95°F under standard conditions and 120°F in the desert test. Indoor temperature and humidity conditions also differ between tests. The amp figures include the compressor and the fan on high. Use the matching data sheet and rating plate when checking a replacement. Mach 3 specifications and Mach 15 specifications.
The locked-rotor rating is the compressor current with the rotor stationary. The two sheets give no measured whole-unit peak for a normal start. For a rough comparison, soft-start maker Micro-Air reports 12–16 amps running and a typical startup range of 25–50 amps for conventional RV units around 13,500–15,000 BTU/h. Confirm the actual starting requirement for your combination before selecting a generator. Micro-Air’s RV current guide
When a second unit makes sense
Another unit deserves consideration when the approved existing system is operating correctly but cannot handle the intended heat load, or when separated spaces need better coverage.
Check distribution first. A larger central unit may still leave a closed bedroom uncomfortable if air cannot reach it. Conversely, a duct or control problem can make a correctly sized system appear inadequate.
Before adding equipment, have the RV maker or qualified installer confirm roof support, mounting location, interior clearance, electrical supply, and control compatibility. A roof opening or an advertisement saying “AC prep” does not establish every installation requirement.
Ducted vs non-ducted cooling
A ducted installation carries conditioned air through built-in ducts to outlets around the RV. A non-ducted installation discharges air through the interior ceiling assembly.
Ducting can improve coverage across the floor plan, but only if the system delivers air properly. Restrictions, poorly sealed sections, or an unsuitable ceiling assembly can undermine the result. Coleman-Mach's FAQs identify blocked airflow and duct problems among causes of weak cooling.
When replacing equipment, identify the rooftop unit, ceiling assembly, control box, and thermostat. Confirm the approved combination before ordering. A matching cooling rating does not prove the new rooftop unit will work with the existing controls.
Power needed on 30-amp and 50-amp service
A standard 30-amp RV hookup provides one 120-volt leg. A standard 50-amp hookup supplies two 120-volt legs, each rated at 50 amps. That gives nominal capacities of 3,600 volt-amps (VA) and 12,000 VA combined. For a load with a power factor of one, those figures also equal watts. Jayco’s shore-power guidance
For air conditioners, use each unit’s published amps to budget a shore-power circuit and its running watts to budget generator power. Also check the generator’s current and receptacle limits. On 50-amp shore power, spare capacity on one leg cannot cover an overload on the other.
For perspective, the two standard-condition running currents in the example table total 27.7A. That leaves little room on a 30A supply even before accounting for other equipment or compressor starts. It is not approval to run that pair together.
Some factory systems manage competing loads. With an approved adapter connecting a 50-amp RV to a 30-amp pedestal, the whole RV shares the pedestal’s 30 amps. Southwire’s adapter guidance Review 30-amp vs 50-amp RV service before planning simultaneous loads.
Never change breaker ratings or wiring to accommodate a larger AC without an approved design.
Generator sizing: check running and starting separately
Use the exact AC's documented running input, including the relevant hot-weather conditions, then add other simultaneous loads. Separately verify that the generator can handle compressor starting demand.
An illustrative running-load calculation uses the Mach 15 example's 1,988W desert-condition input plus an assumed 400W of other equipment:
1,988W + 400W = 2,388W running load.
The 400 W represents loads you would replace with your own figures. For the separate starting check, count the AC’s starting demand together with the loads already running. Count the AC once during that event. Check the generator’s rated continuous output, short-duration surge capability and outlet limits.
A generator rated for only 2,000W continuous output cannot support that illustrative combined running load, even if a soft start helps the compressor begin turning.
Both Coleman-Mach data sheets call for considering total RV consumption and note reduced generator capacity with altitude, heat, and poor maintenance. Use the generator maker's applicable output and derating instructions. The RV generator sizing guide explains the full load-list method.
What a soft start changes
A compatible soft start limits the brief current surge as the compressor gets up to speed. This matters most when a generator can carry the running load but struggles at the instant the compressor starts.
If the generator overloads after the compressor has been running for a while, revisit the running-load total, the other appliances and the operating conditions. Reducing the startup surge cannot supply the missing continuous power.
Check whether the exact AC already includes a factory starting aid and whether an aftermarket device is approved. Have installation and commissioning performed according to both makers' instructions. Compare RV air conditioner soft starts by compatibility before considering claimed startup reductions.
Reduce heat load before buying more capacity
Shade, window coverings, and fewer indoor heat sources can reduce the cooling task. Keep doors and windows closed while cooling, subject to required appliance ventilation.
Start cooling before a severe heat buildup where practical. Dometic's AirCommand operating guidance recommends early operation during extreme heat, along with shading and reducing heat-producing appliance use.
A roof fan can help exchange hot air when ventilation is the chosen cooling method; compare RV roof vent fans. Avoid routinely exhausting cooled air outdoors while expecting the AC to maintain a closed-space cooling load.
Keep filters maintained and outlets unobstructed. Follow the exact manual for owner maintenance and leave rooftop servicing to qualified personnel.
What to gather before choosing
Prepare a short equipment and use record:
- RV model, floor plan, intended climate, and existing cooling performance.
- Rooftop AC, ceiling assembly, thermostat, and control-box identifiers.
- Shore-power service and other simultaneous loads.
- Generator continuous output, starting capability, and operating conditions.
- Approved mounting, electrical, and replacement requirements.
Use that record to compare RV air conditioners. Obtain a complete compatibility assessment rather than ordering from the BTU label alone.
Common mistakes
Avoid treating length charts as final sizing, assuming 15,000 BTU means a large leap over 13,500, or confusing electrical watts with cooling output.
Also avoid buying for generator peak wattage alone, treating a soft start as a reduction in continuous load, or upgrading capacity before checking weak airflow. A complete installation needs the cooling, distribution, controls, and power supply to work together.
FAQ
Is 13,500 BTU enough for an RV?
It can be, but length alone cannot answer the question. Consider the RV's insulation, windows, floor plan, shade, climate, and existing cooling performance. Check the RV maker's approved equipment. A compact, well-insulated vehicle in moderate conditions presents a different cooling load from a sunny, open-slide installation.
Is a 15,000 BTU RV AC much stronger than a 13,500?
It has 1,500 BTU/h more nominal cooling capacity, about an 11% increase relative to 13,500 BTU/h. That can help when one unit is slightly short of capacity, but it does not double cooling or ensure comfortable temperatures throughout separate rooms. Air distribution and heat gain still matter.
Can two RV air conditioners run on 30-amp service?
Check the coach manual for an approved two-unit operating mode on 30-amp service. The two example units already total 27.7 amps running under standard conditions, before the converter or other appliances draw power. A soft start can ease startup, but both units and the other loads still have to fit the supply.
Will a soft start let a small generator run any RV AC?
No. A compatible soft start can reduce compressor starting demand, but the generator still needs enough continuous output for the AC and other loads. Check the exact combination and account for operating conditions. A unit that starts successfully can still overload a generator during sustained hot-weather use.
Does a ducted RV air conditioner cool better?
Ducting can distribute air to more areas, but the result depends on the layout and condition of the installation. Restricted or leaking ducts can limit delivery. A non-ducted unit discharges through its ceiling assembly, which may suit an open floor plan. Choose an approved system for the RV rather than assuming one design always wins.
Sources
- https://www.dometic.com/en-au/lp/ac-buying-guide2
- https://campaigns.coleman-mach.com/hubfs/382x3%20Mach%203%20AC%20Standard-DQ-Roughneck%207-8-24.pdf?hsLang=en
- https://campaigns.coleman-mach.com/hubfs/382x4%20Mach%2015%20AC%20Standard-DQ-Roughneck%207-8-24.pdf?hsLang=en
- https://www.microair.net/blogs/news/how-many-amps-does-an-rv-ac-draw
- https://coleman-mach.com/service-support/faqs/
- https://www.jayco.com/uploads/rvs/manuals/645-Jayco-Family-Towable-Manual-Vs2---2026---WEB.pdf
- https://www.southwire.com/rv-power
- https://media.dometic.com/externalassets/dometic-aircommand-13500_9108878728_65540.pdf
- https://www.eaton.com/sg/en-us/products/backup-power-ups-surge-it-power-distribution/backup-power-ups/powerfactor/difference-between-va-watts.html